- * Dimensions: 44mm×22.5mm(Φ×H)
- * Output: 4 to 20mA
- * Supply voltage: 11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
- * Input: RTD, TC, Ohm, mV
- * Operation: HART-protocol
- * Galvanic isolation(In/Out): 2KVAC
- * Installation: sensor head Form B
DUS-F6 - Clip-on Energy meter
- Hose material: Metal/ Rigid plastic tube made of PCV, PP or PVDF
- Liquid type: Water/Other (fluids without solid particles or impurities)
- 0-75° (no surface freezing)
- Low speed cut-off value: 0.1m/s
- Display: 256*128, LCD
- Response time: 0.5-60s
- Accuracy: +/-2%, (+/-1% after calibration)
- Data storage period: 300ms
- Memory for data saving: EEPROM, data storage more than 10 years
- I/O power supply: M12 type aviation plug
- Output: 4-20mA
- Communication: Modbus RS485
- Option for output: OCT, alarm relay
- Power supply: 10-24VVDC
- Electrical power : <3W
- Ambient temperature : -10° to 60°C
- Cable length: 2m, PT100 sensor cable length is 9m
-
Garanties sécurité
-
Politique de livraison
-
Politique retours
The DUS-F6 energy meter is easy to install and operate. It is quick to install, taking only a few minutes.
The E6 adopts a new compact design, adapting to different DN.
It has a 256*128 screen for optimal display.
This flowmeter is also available in an energy meter version: DUS-E6, including PT1000 probes.
DUS-F6
Reviews
No customer reviews for the moment.
16 other products in the same category:
For all clear, non biphasic liquids and all types of pipes from DN20 to DN 1200 :
- Measurement accuracy 1% F.S
- Communications : 4~20 mA & RS485 Modbus
- Programmable data logger 16 GB SD card
- Battery 16 hours autonomy
- Non-invasive transducers Stainless steel IP68
- Mounting rails for optimal measurement
- Energy metering included
- 2x TT02 IP68 transducers
- -40 °C ~ 80 °C (130°C optional)
- Suitable for pipes DN 20 mm to DN 1200 mm
- Mounting rails with strip and clamps
- Standard cable length: 5 meters
- 2x non-intrusive PT100 IP68 temperature sensors
- Measurement of thermal & cooling energy
€2,500.00
Price
- Universally progammable with HART-protocol for various input signals
- Two-wire technology, analogue output 4 to 20mA
- Highly accurate in entire operating temperature range
- Wide voltage supply range
- Customer specific measurement range settings
- Simple and user friendly software
- Multiparametric backlight rotatable LCD display
- Thermal & cooling energy Advanced technology & electronics
- Easy to install & use
- Accuracy, stability & longevity
- Communications & remote reading
- Compact & robust design
- Vertical or horizontal mounting
- Multifunctional display/ 8 digit LCD screen
- Long life battery or power supply
- Suitable for lower water quality
- Communication : e-HART
- Output : 4 to 20mA
- Supply voltage : 7.5 to 45VDC
- Input : RTC, TC, Ohm, mV
- Cold junction : Internal
- Accuracy (Pt100) : <0,2K or 0,08%
- Influence of ambient : Negligible
- Load influence : Negligible
- Power supply influence : Negligible
- Resolution : 0.3uA
- Galvanic isolation (In/Out) : 2KVAC
- Installation : DIN Rail
- Storage temperature ; Atmospheric temperature
- Operating ambient temperature : -20°C to +60° C
- Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
- Can be offered for higher temperatures with other capsule combinaisons
- Setpoint repeatability : ± 1% of FSR
- Enclosure : Die cast aluminium to IP 66
- Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
- Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available
- Universal settings with HART-protocol for various input signals
- 2 wire technology, 4 to 20mA analogue output
- High accuracy in total ambient temperature range
- Galvanic isolation
- An internal temperature sensor of active temperature compensation
- Wide voltage supply range
- Customer specific measurement range settings
- Simple and user friendly software
- Multiparametric backlight rotatable LCD display
- Range: 0-20 mg/L, 0-200%, 0-400 hPa
- Resolution: 0.01 mg/L, 0.1%, 1 hPa
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%; 50Hz/60Hz
- Communication protocol: MODBUS-RTU standard (customizable)
- Operating temperature: 0~60 °C
- Measure range: pH: 0-14 pH, ±0.02pH;
- ORP: -1000 ~1000mV, ±1mV
- Input Resistance: ≥10~12Ω
- Temperature compensation : Manual/ Auto temperature compensation
- Signal output : 4-20mA, maximum loop 750Ω, 0.2%FS
- Communication : RS485 Modbus-RTU
- Relay output : 250V, 3A
- Power supply: 220V±10%,50Hz/60Hz
€250.00
Price
- Output: 4 to 20mA
- Supply voltage: 7.5 to 45VDC
- Input: RTD, TC, Ohm, mV
- Cold junction: Internal
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence: Negligible
- Resolution: 0.3uA
- Installation: sensor head Form B
- Operation: PC-programmable
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
Applications :
- Compressors
- R.O Plants
Specifications :
- SS316 & Teflon as standard wetted parts
- Electrical Rating : 5A, 250VAC;0.2A,250VDC(res)
- Pressure port : 1/4" BSPM
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP