- IIoT capability
- Integrated pressure sensor with stainless steel diaphragm
- Accuracy 0.25% standard (finer accuracies are available)
- OLED color display
- Easy to use via a mobile application in real time
- Possibility to set parameters via a dashboard
- 4 relays, switch-on and switch-off points can be set independently
- Possibility to program a delayed measurement
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
-
Garanties sécurité
-
Politique de livraison
-
Politique retours
This is a PC programmable temperature transmitter to convert Pt100 input signals into a 4 to 20mA modulable analog output signal.
No customer reviews for the moment.
- Communication : e-HART
- Output : 4 to 20mA
- Supply voltage : 7.5 to 45VDC
- Input : RTC, TC, Ohm, mV
- Cold junction : Internal
- Accuracy (Pt100) : <0,2K or 0,08%
- Influence of ambient : Negligible
- Load influence : Negligible
- Power supply influence : Negligible
- Resolution : 0.3uA
- Galvanic isolation (In/Out) : 2KVAC
- Installation : DIN Rail
- Input: RTD
- Type:pt100
- Accuracy:0.2K or 0.1% of spanPerformance characteristics
- Response time: 1s
- Reference condition : Calibration temperature:+23°C(73.4K)±5K
- Long term stability:≤0.05%year
- Switch on delay:≤5s
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence:Negligible
- Resolution:1μA·Storage temperature
- Ambient temperature limits:40 to +85 °C (-40 to 185 °F)
- Storage temperature: -40 to +100 °C (-40 to 212 °F)
- Condensation: Allowable
- Degree of protection:IP00/IP66 installed
- Shock and vibration resistance:4g/2 to150 Hz as per IEC 60 068-26
- Electromagnetic compatibility (EMC) : Interference immunity and interference emission
- GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
* Output: 4 to 20mA * Supply voltage: 7.5 to 45VDC * Input: RTD, TC, Ohm, mV * Cold junction: Internal * Galvanic isolation: 2KVAC(In/Out) * Influence of ambient: Negligible * Load influence: Negligible * Power supply influence: Negligible * Resolution: 0.3uA * Installation: sensor head Form B * Operation: PC-programmable * Weight: approx. 35g * Dimensions: 44mm×24mm(Φ×H) |
- Thermal & cooling energy Advanced technology & electronics
- Easy to install & use
- Accuracy, stability & longevity
- Communications & remote reading
- Compact & robust design
- Vertical or horizontal mounting
- Multifunctional display/ 8 digit LCD screen
- Long life battery or power supply
- Suitable for lower water quality
For all clear, non-diphasic liquids and for all types of pipes from DN20 to DN1200:
- Accuracy of measurement 1 % F.S.
- Communications : 4~20 mA & RS485 Modbus
- Programmable data logger 16 GB SD card
- 16 hours battery life
- Non-invasive transducers Stainless steel IP68
- Mounting rails for optimal measurement
- 2x TT02 Transducers IP68 DN20 to DN1200
-40 °C ~ 80°C - Mounting rails with strip and clamps
- Standard cable length: 5 meters
- Optional energy meter
- Storage temperature ; Atmospheric temperature
- Operating ambient temperature : -20°C to +60° C
- Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
- Can be offered for higher temperatures with other capsule combinaisons
- Setpoint repeatability : ± 1% of FSR
- Enclosure : Die cast aluminium to IP 66
- Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
- Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available
- Storage temperature ; Atmospheric temperature
- Operating ambient temperature : -20°C to +60° C
- Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
- Can be offered for higher temperatures with other capsule combinaisons
- Setpoint repeatability : ± 1% of FSR
- Enclosure : Die cast aluminium to IP 66
- Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
- Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available
- Universal settings with HART-protocol for various input signals
- 2 wire technology, 4 to 20mA analogue output
- High accuracy in total ambient temperature range
- Galvanic isolation
- An internal temperature sensor of active temperature compensation
- Wide voltage supply range
- Customer specific measurement range settings
- Simple and user friendly software
- Multiparametric backlight rotatable LCD display
Applications :
- Compressors
- R.O Plants
Specifications :
- SS316 & Teflon as standard wetted parts
- Electrical Rating : 5A, 250VAC;0.2A,250VDC(res)
- Pressure port : 1/4" BSPM
Features
- Range: 0.01 electrode: 0.02~20.00us/cm
- 0.1 electrode: 0.2~200.0us/cm
- 1.0 electrode: 2~2000us/cm
- 10.0 electrode: 0.02~20ms/cm
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%, 50Hz/60Hz
- Operating temperature: 0~60°C
- Accuracy : ± 2 % PE
- Measuring medium: Liquid
- Relay output: 250 VAC, 3A
- Hose material: Metal/ Rigid plastic tube made of PCV, PP or PVDF
- Liquid type: Water/Other (fluids without solid particles or impurities)
- 0-75° (no surface freezing)
- Low speed cut-off value: 0.1m/s
- Display: 256*128, LCD
- Response time: 0.5-60s
- Accuracy: +/-2%, (+/-1% after calibration)
- Data storage period: 300ms
- Memory for data saving: EEPROM, data storage more than 10 years
- I/O power supply: M12 type aviation plug
- Output: 4-20mA
- Communication: Modbus RS485
- Option for output: OCT, alarm relay
- Power supply: 10-24VVDC
- Electrical power : <3W
- Ambient temperature : -10° to 60°C
- Cable length: 2m, PT100 sensor cable length is 9m
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP
*Output: 4 to 20mA
*Supply voltage: 7.5 to 45VDC
*Input: RTD, TC, Ohm, mV
*Accuracy(Pt100): <0.2K or 0.08%
*Cold junction: Internal
*Galvanic isolation: 2 KVAC(In/Out)
*Influence of ambient: Negligible
*Load influence: Negligible
*Power supply influence: Negligible
*Resolution: 0.3uA
*Operation: HART-protocol
*Installation: sensor head Form B
*Dimensions: 44mm×24mm(Φ×H)
*Weight: approx. 35g
- Storage temperature ; Atmospheric temperature
- Operating ambient temperature : -20°C to +60° C
- Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
- Can be offered for higher temperatures with other capsule combinaisons
- Setpoint repeatability : ± 1% of FSR
- Enclosure : Die cast aluminium to IP 66
- Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
- Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available