- Storage temperature ; Atmospheric temperature
- Operating ambient temperature : -20°C to +60° C
- Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
- Can be offered for higher temperatures with other capsule combinaisons
- Setpoint repeatability : ± 1% of FSR
- Enclosure : Die cast aluminium to IP 66
- Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
- Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available
KU Series pressure switches
Applications :
- Compressors
- R.O Plants
Specifications :
- SS316 & Teflon as standard wetted parts
- Electrical Rating : 5A, 250VAC;0.2A,250VDC(res)
- Pressure port : 1/4" BSPM
-
Garanties sécurité
-
Politique de livraison
-
Politique retours
KU Series pressure switches are low cost option housed in pressed steel powder coated enclosure and are recommended for panel mounting or indoor service. The repeat accuracy is better than +/- 1,5% FSR, Pressure port is 1/4" BSPM Standard.
KU
Reviews
No customer reviews for the moment.
16 other products in the same category:
For all clear, non biphasic liquids and all types of pipes from DN20 to DN 1200 :
- Measurement accuracy 1% F.S
- Communications : 4~20 mA & RS485 Modbus
- Programmable data logger 16 GB SD card
- Battery 16 hours autonomy
- Non-invasive transducers Stainless steel IP68
- Mounting rails for optimal measurement
- Energy metering included
- 2x TT02 IP68 transducers
- -40 °C ~ 80 °C (130°C optional)
- Suitable for pipes DN 20 mm to DN 1200 mm
- Mounting rails with strip and clamps
- Standard cable length: 5 meters
- 2x non-intrusive PT100 IP68 temperature sensors
- Measurement of thermal & cooling energy
€2,500.00
Price
- Range: 0-20 mg/L, 0-200%, 0-400 hPa
- Resolution: 0.01 mg/L, 0.1%, 1 hPa
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%; 50Hz/60Hz
- Communication protocol: MODBUS-RTU standard (customizable)
- Operating temperature: 0~60 °C
- Hose material: Metal/ Rigid plastic tube made of PCV, PP or PVDF
- Liquid type: Water/Other (fluids without solid particles or impurities)
- 0-75° (no surface freezing)
- Low speed cut-off value: 0.1m/s
- Display: 256*128, LCD
- Response time: 0.5-60s
- Accuracy: +/-2%, (+/-1% after calibration)
- Data storage period: 300ms
- Memory for data saving: EEPROM, data storage more than 10 years
- I/O power supply: M12 type aviation plug
- Output: 4-20mA
- Communication: Modbus RS485
- Option for output: OCT, alarm relay
- Power supply: 10-24VVDC
- Electrical power : <3W
- Ambient temperature : -10° to 60°C
- Cable length: 2m, PT100 sensor cable length is 9m
For all clear, non-diphasic liquids and for all types of pipes from DN20 to DN1200:
- Accuracy of measurement 1 % F.S.
- Communications : 4~20 mA & RS485 Modbus
- Programmable data logger 16 GB SD card
- 16 hours battery life
- Non-invasive transducers Stainless steel IP68
- Mounting rails for optimal measurement
- 2x TT02 Transducers IP68 DN20 to DN1200
-40 °C ~ 80°C - Mounting rails with strip and clamps
- Standard cable length: 5 meters
- Optional energy meter
€2,250.00
Price
- Output: 4 to 20mA
- Supply voltage: 7.5 to 45VDC
- Input: RTD, TC, Ohm, mV
- Cold junction: Internal
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence: Negligible
- Resolution: 0.3uA
- Installation: sensor head Form B
- Operation: PC-programmable
- Storage temperature ; Atmospheric temperature
- Operating ambient temperature : -20°C to +60° C
- Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
- Can be offered for higher temperatures with other capsule combinaisons
- Setpoint repeatability : ± 1% of FSR
- Enclosure : Die cast aluminium to IP 66
- Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
- Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
- Communication : e-HART
- Output : 4 to 20mA
- Supply voltage : 7.5 to 45VDC
- Input : RTC, TC, Ohm, mV
- Cold junction : Internal
- Accuracy (Pt100) : <0,2K or 0,08%
- Influence of ambient : Negligible
- Load influence : Negligible
- Power supply influence : Negligible
- Resolution : 0.3uA
- Installation : DIN Rail
- Storage temperature ; Atmospheric temperature
- Operating ambient temperature : -20°C to +60° C
- Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
- Can be offered for higher temperatures with other capsule combinaisons
- Setpoint repeatability : ± 1% of FSR
- Enclosure : Die cast aluminium to IP 66
- Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
- Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available
- Input: RTD
- Type:pt100
- Accuracy:0.2K or 0.1% of spanPerformance characteristics
- Response time: 1s
- Reference condition : Calibration temperature:+23°C(73.4K)±5K
- Long term stability:≤0.05%year
- Switch on delay:≤5s
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence:Negligible
- Resolution:1μA·Storage temperature
- Ambient temperature limits:40 to +85 °C (-40 to 185 °F)
- Storage temperature: -40 to +100 °C (-40 to 212 °F)
- Condensation: Allowable
- Degree of protection:IP00/IP66 installed
- Shock and vibration resistance:4g/2 to150 Hz as per IEC 60 068-26
- Electromagnetic compatibility (EMC) : Interference immunity and interference emission
- GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
- Universal settings with HART-protocol for various input signals
- 2 wire technology, 4 to 20mA analogue output
- High accuracy in total ambient temperature range
- Galvanic isolation
- An internal temperature sensor of active temperature compensation
- Wide voltage supply range
- Customer specific measurement range settings
- Simple and user friendly software
- Multiparametric backlight rotatable LCD display
Features
- Range: 0.01 electrode: 0.02~20.00us/cm
- 0.1 electrode: 0.2~200.0us/cm
- 1.0 electrode: 2~2000us/cm
- 10.0 electrode: 0.02~20ms/cm
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%, 50Hz/60Hz
- Operating temperature: 0~60°C
- Accuracy : ± 2 % PE
- Measuring medium: Liquid
- Relay output: 250 VAC, 3A