- Input: RTD
- Type:pt100
- Accuracy:0.2K or 0.1% of spanPerformance characteristics
- Response time: 1s
- Reference condition : Calibration temperature:+23°C(73.4K)±5K
- Long term stability:≤0.05%year
- Switch on delay:≤5s
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence:Negligible
- Resolution:1μA·Storage temperature
- Ambient temperature limits:40 to +85 °C (-40 to 185 °F)
- Storage temperature: -40 to +100 °C (-40 to 212 °F)
- Condensation: Allowable
- Degree of protection:IP00/IP66 installed
- Shock and vibration resistance:4g/2 to150 Hz as per IEC 60 068-26
- Electromagnetic compatibility (EMC) : Interference immunity and interference emission
- GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
- Storage temperature ; Atmospheric temperature
- Operating ambient temperature : -20°C to +60° C
- Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
- Can be offered for higher temperatures with other capsule combinaisons
- Setpoint repeatability : ± 1% of FSR
- Enclosure : Die cast aluminium to IP 66
- Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
- Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available
-
Garanties sécurité
-
Politique de livraison
-
Politique retours
MT switches have been designed for applications that require robust, long lasting switches, coupled with high accuracy and repeatability, in adverse conditions. By using appropriate capsules and wetted parts, MT series pressure switches can be used for thousands of applications. A wide choice of electrical elements including SPDT, DPDT, gold plated contacts make these switches ideal for a variety of critical applications. A wide scale, when opted for, offers ease of setting, given the smaller least counts.
No customer reviews for the moment.
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
- * Dimensions: 44mm×22.5mm(Φ×H)
- * Output: 4 to 20mA
- * Supply voltage: 11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
- * Input: RTD, TC, Ohm, mV
- * Operation: HART-protocol
- * Galvanic isolation(In/Out): 2KVAC
- * Installation: sensor head Form B
- IIoT capability
- Integrated pressure sensor with stainless steel diaphragm
- Accuracy 0.25% standard (finer accuracies are available)
- OLED color display
- Easy to use via a mobile application in real time
- Possibility to set parameters via a dashboard
- 4 relays, switch-on and switch-off points can be set independently
- Possibility to program a delayed measurement
- Communication : e-HART
- Output : 4 to 20mA
- Supply voltage : 7.5 to 45VDC
- Input : RTC, TC, Ohm, mV
- Cold junction : Internal
- Accuracy (Pt100) : <0,2K or 0,08%
- Influence of ambient : Negligible
- Load influence : Negligible
- Power supply influence : Negligible
- Resolution : 0.3uA
- Galvanic isolation (In/Out) : 2KVAC
- Installation : DIN Rail
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP
- Communication : e-HART
- Output : 4 to 20mA
- Supply voltage : 7.5 to 45VDC
- Input : RTC, TC, Ohm, mV
- Cold junction : Internal
- Accuracy (Pt100) : <0,2K or 0,08%
- Influence of ambient : Negligible
- Load influence : Negligible
- Power supply influence : Negligible
- Resolution : 0.3uA
- Galvanic isolation (In/Out) : 2KVAC
- Installation : DIN Rail
- Thermal & cooling energy Advanced technology & electronics
- Easy to install & use
- Accuracy, stability & longevity
- Communications & remote reading
- Compact & robust design
- Vertical or horizontal mounting
- Multifunctional display/ 8 digit LCD screen
- Long life battery or power supply
- Suitable for lower water quality
*Output: 4 to 20mA
*Supply voltage: 7.5 to 45VDC
*Input: RTD, TC, Ohm, mV
*Accuracy(Pt100): <0.2K or 0.08%
*Cold junction: Internal
*Galvanic isolation: 2 KVAC(In/Out)
*Influence of ambient: Negligible
*Load influence: Negligible
*Power supply influence: Negligible
*Resolution: 0.3uA
*Operation: HART-protocol
*Installation: sensor head Form B
*Dimensions: 44mm×24mm(Φ×H)
*Weight: approx. 35g
- Universally progammable with HART-protocol for various input signals
- Two-wire technology, analogue output 4 to 20mA
- Highly accurate in entire operating temperature range
- Wide voltage supply range
- Customer specific measurement range settings
- Simple and user friendly software
- Multiparametric backlight rotatable LCD display
- Measure range: pH: 0-14 pH, ±0.02pH;
- ORP: -1000 ~1000mV, ±1mV
- Input Resistance: ≥10~12Ω
- Temperature compensation : Manual/ Auto temperature compensation
- Signal output : 4-20mA, maximum loop 750Ω, 0.2%FS
- Communication : RS485 Modbus-RTU
- Relay output : 250V, 3A
- Power supply: 220V±10%,50Hz/60Hz
For all clear, non biphasic liquids and all types of pipes from DN20 to DN 1200 :
- Measurement accuracy 1% F.S
- Communications : 4~20 mA & RS485 Modbus
- Programmable data logger 16 GB SD card
- Battery 16 hours autonomy
- Non-invasive transducers Stainless steel IP68
- Mounting rails for optimal measurement
- Energy metering included
- 2x TT02 IP68 transducers
- -40 °C ~ 80 °C (130°C optional)
- Suitable for pipes DN 20 mm to DN 1200 mm
- Mounting rails with strip and clamps
- Standard cable length: 5 meters
- 2x non-intrusive PT100 IP68 temperature sensors
- Measurement of thermal & cooling energy
- Hose material: Metal/ Rigid plastic tube made of PCV, PP or PVDF
- Liquid type: Water/Other (fluids without solid particles or impurities)
- 0-75° (no surface freezing)
- Low speed cut-off value: 0.1m/s
- Display: 256*128, LCD
- Response time: 0.5-60s
- Accuracy: +/-2%, (+/-1% after calibration)
- Data storage period: 300ms
- Memory for data saving: EEPROM, data storage more than 10 years
- I/O power supply: M12 type aviation plug
- Output: 4-20mA
- Communication: Modbus RS485
- Option for output: OCT, alarm relay
- Power supply: 10-24VVDC
- Electrical power : <3W
- Ambient temperature : -10° to 60°C
- Cable length: 2m, PT100 sensor cable length is 9m
- Storage temperature ; Atmospheric temperature
- Operating ambient temperature : -20°C to +60° C
- Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
- Can be offered for higher temperatures with other capsule combinaisons
- Setpoint repeatability : ± 1% of FSR
- Enclosure : Die cast aluminium to IP 66
- Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
- Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available