Active filters
  • Measuring range: 10kPa-3MPa
  • Output signal: 4-20mA, 4-20mA + HART, 0.5-4.5VDC, Modbus-RTU / RS485 ...
  • Accuracy: ± 0.2% URL, ± 0.5% URL
  • Fluid temperature: -40 to 120 ° C
  • Measurement: pressure, level, differential pressure, density, flow
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% of URL / 1 year
  • Process connection: Tri-Clamp 1-1 / 2 ", Tri-Clamp 2", DIN32676 DN32, ISO2852, DRD
  • Certificates: 3A, EHEDG, CE, RoHS, Ex-proof
  • Measuring range: 2kPa-10MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.15% URL, optional ± 0.1% URL
  • Operating temperature: -40-85, LCD display: -20-70 ℃
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, IECEx, NEPSI, RoHS, CE
  • Measuring range: 200Pa-10MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Operating temperature: -40-85, LCD display: -40-120 ℃
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, IECEx, NEPSI, RoHS, CE
  • Measuring range: 200Pa-10MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Operating temperature: -40-85, LCD display: -40-120 ℃
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, MC, NEPSI, CE
  • Measuring range: 10kPa-1MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.1% URL, optional ± 0.075% URL
  • Substrate temperature: -40-120
  • Measuring medium: pressure, level, differential pressure, density, interface, flow
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 5 years
  • Process connection: DN50PN10, DN80PN10, DN100PN10
  • Approvals: CE, EX- certificate of proof
  • Measuring range: 200Pa-40MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, IECEx, NEPSI, RoHS, CE
  • Measuring range: 200Pa-40MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, MC, NEPSI,, CE
  • Measuring range: 200Pa-10MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.15% URL, optional ± 0.1% URL
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, MC, NEPSI, CE
  • Measuring range: 10kPa-1MPa
  • Output signal: 4-20mA, 4-20mA + HART ...
  • Accuracy: ± 0.1% URL, ± 0.075% URL
  • Substrate temperature: -40-120 ° C
  • Measurement: pressure, level, differential pressure, density, flow
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C ...
  • Stability: ± 0.2% of URL / 5 years
  • Process connection: DN50 PN10, DN80 PN10, DN100 PN10
  • Certificates: CE, EX- test certificate
  • Measuring range: 4kPa-1MPa
  • Output signal: 4-20mA, 4-20mA + HART ...
  • Accuracy: ± 0.2% URL, ± 0.5% URL
  • Substrate temperature: -40 to 120 ° C
  • Measurement: pressure, level, differential pressure, density, flow
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% of URL / 5 years
  • Process connection: DN50 PN10, DN80 PN10, DN100 PN10, Tri-Clamp 1-1 / 2 ", Tri-Clamp 2"
  • Approvals: CE certificate, EX-proof
  • Measuring range : 2 kPa at 40 MPa (20 mBar at 40 bar)
  • Output signal: 4-20mA, 4-20mA + HART, 0-5 VDC, Modbus-RTU / RS485, others
  • Accuracy: ± 0.1% URL, optional ± 0.075% URL
  • Process connection: M20 * 1.5, 1/2 "G, 1/4" G, 1/2 "NPT or 1/4" NPT
  • Measuring medium: liquid, gas or vapor
  • Fluid temperature: -30 to 80 ° C
  • Electrical connection: DIN43650 IP65 or M12 * 1 (4 pins) IP67