Theme Features - you can manage from admin

Select Theme
Custome Color 1
Custome Color 2
Box-Layout
Background Pattern

Custome background also available in admin.

Background color
Wow Animation Enable
Slider 3D Animation Enable
Menu Sticky Enable
Bottom Option Enable
Filter By
Four d’étalonnage à bloc sec portatif
Four d’étalonnage à bloc sec portatif
Grid
List

There are 8 products.

Grid
List
Showing 1-8 of 8 item(s)
Active filters

Accuracy: ± 0.3 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 7 minutes
Temperature unit: Selectable °C or °F
Well diameter: 19 mm
Immersion length: 100 mm
Heating time: 14 minutes (ambient to 123 °C)
Cooling time: 34 minutes (123 °C to (-)40 °C)
Interchangeable insert: Well for Ø 1/4’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 100 V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable

Temperature range: (-)10°C ~120°C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
                    25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided
Plage de température : 50 °C ~ 350 °C
Accuracy: ± 0.4 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 25 mm
Immersion length: 110 mm
Heating time: 20 minutes (ambient to 350 °C)
Cooling time: 33 minutes (350 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz, 520 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable
Température range : 50 °C ~ 650 °C
Accuracy: ± 0.6 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 25 mm
Immersion length: 110 mm
Heating time: 20 minutes (ambient to 650 °C)
Cooling time: 42 minutes (650 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz, 1230 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 11 kg
Enclosure type: Portable

Température range : 50 °C ~ 650 °C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
                    25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided

Température range: 50 °C ~ 650 °C 300 °C ~ 1200 °C
Accuracy: ± 2 °C
Stability: ± 0.3 °C
Resolution: 0.1 °C
Stabilization time: 15 minutes
Temperature unit: Selectable °C or °F
Well diameter: 30 mm
Immersion length: 105 mm
Heating time: 30 minutes (100 °C to 800 °C)
Cooling time: 120 minutes (800 °C to 200 °C)
Communication port: Standard RS232 port
Calibration software: Standard MET-CAL software included
Switch test: Provided
Power supply / Consumption: 230V AC, 50 Hz & 115V AC switchable, 60 Hz
Dimensions (L x W x H) / Weight: 160 x 365 x 450 mm / 11 kg
Enclosure type: Portable
Carrying case: Included
ISO17025 calibration certificate: Included
Temperature range: 300 °C ~ 1200 °C
Accuracy: ± 2 °C
Stability: ± 0.5 °C
Resolution: 1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 26 mm
Immersion length: 105 mm
Heating time: 60 minutes (ambient to 1200 °C)
Cooling time: 45 minutes (1200 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz / 115 V AC, 60 Hz, 650 W, switchable
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable

  • Temperature range: -100°C to +25°C
  • Accuracy: ± 0.3 °C
  • Stability: ± 0.05 °C
  • Resolution:Stabilization time: 15 minutes
    • 0.01°C (from +25 to +19.99°C)
    • 0.1°C (from 20°C to -100°C)
  • Temperature unit: Selectable °C or °F
  • Well diameter: 30 mm
  • Immersion length: 150 mm
  • Heating time: 50 minutes (from ambient to maximum)
  • Cooling time:Switch test: Provided
    • 40 minutes (from +25°C to -60°C)
    • 50 minutes (from -60°C to -100°C)
  • Power supply / Consumption: 90 ~ 220 V AC, 50/60 Hz
  • Dimensions (L x P x H) : 439 x 240 x 358 mm
  • Weight: 15 kg
  • Calibration certificate: Factory traceable to ISO17025 included or ISO17025 certificate from an accredited lab