Subcategories
- Pressure range: -0.9 to 60 bar
- Media: Air
- Resolution: 1 mbar
- Connections Standard instruments: 3/8 BSP F
- Connections Instruments test: 1/4 BSP F
- Nylon hose 1 meter with suitable connector
- Ergonomics & Ease of use
- Robust Design & Stable Performance
- No specific maintenance to be expected
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided
Température range : 50 °C ~ 650 °C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided
Accuracy: ± 0.3 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 7 minutes
Temperature unit: Selectable °C or °F
Well diameter: 19 mm
Immersion length: 100 mm
Heating time: 14 minutes (ambient to 123 °C)
Cooling time: 34 minutes (123 °C to (-)40 °C)
Interchangeable insert: Well for Ø 1/4’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 100 V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 25 mm
Immersion length: 110 mm
Heating time: 20 minutes (ambient to 350 °C)
Cooling time: 33 minutes (350 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz, 520 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 25 mm
Immersion length: 110 mm
Heating time: 20 minutes (ambient to 650 °C)
Cooling time: 42 minutes (650 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz, 1230 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 11 kg
Enclosure type: Portable
- Pressure: Differential
- Details: 0.05% of full scale
- 11 Units: Pa, kPa, MPa, PSI, Kg / cm², Bar, mmBar, cmH20 ...
- Display: Large LCD screen 5 or 6 Digit & Bargraph in%
- 7 function keys
- Temperature compensation from 0 to 50 ° C
- 60 hour rechargeable lithium battery
- Integrated data logger
- Clean design & high performance
- CE & Exia II CT4Ga approved
- Calibration certificate with factory traceability