Theme Features - you can manage from admin

Select Theme
Custome Color 1
Custome Color 2
Box-Layout
Background Pattern

Custome background also available in admin.

Background color
Wow Animation Enable
Slider 3D Animation Enable
Menu Sticky Enable
Bottom Option Enable
Produits
  • Featured
Pneumatic Pressure: -0.85 to 20 bar.
Hydraulic Pressure: 0 to 400 bar.
Accuracy: ±0.025% FS.
Temperature Compensation: Automatic from 0 to 50 °C.
Selectable Pressure Units: kg/cm², psi, bar, mbar, etc.
Current Input: 50 mA active, 25 mA passive, 800 Ω resistance.
Voltage Input: 0 to 30 VDC, resolution 0.01 (mA/V).
Switch Test: Up to 5 VDC.
Media: Air and oil.
Overpressure Alarm: 120% FS (visual and audible).
Pressure Generation: Built-in pumps with fine adjustment vernier.
Power Supply: Rechargeable 7.2 Volts (AA) battery.
Operating Temperature: 15 °C to 40 °C.
Storage Temperature Range: 10 °C to 60 °C.
Protection Class: IP10.
Zero Adjustment: Automatic if pressure is less than 1% FS.

  • Pneumatic Pressure: -0.85 to 20 bar.
  • Hydraulic Pressure: 0 to 400 bar.
  • Accuracy: ±0.025% FS.
  • Temperature Compensation: Automatic from 0 to 50 °C.
  • Selectable Pressure Units: kg/cm², psi, bar, mbar, etc.
  • Current Input: 50 mA active, 25 mA passive, 800 Ω resistance.
  • Voltage Input: 0 to 30 VDC, resolution 0.01 (mA/V).
  • Switch Test: Up to 5 VDC.
  • Media: Air and oil.
  • Overpressure Alarm: 120% FS (visual and audible).
  • Pressure Generation: Built-in pumps with fine adjustment vernier.
  • Power Supply: Rechargeable 7.2 Volts (AA) battery.
  • Operating Temperature: 15 °C to 40 °C.
  • Storage Temperature Range: 10 °C to 60 °C.
  • Protection Class: IP10.
  • Zero Adjustment: Automatic if pressure is less than 1% FS.
Models: PPC-H + (accuracy 0.025% FS)
Pressure Range: 0 to 400 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.
Models: PPC-H + (accuracy 0.025% FS)
Pressure Range: 0 to 200 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.
Models: PPC-H (accuracy 0.05% FS)
Pressure Range: 0 to 400 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.
Models: PPC-H (accuracy 0.05% FS)
Pressure Range: 0 to 200 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.

Pressure range: -0.85 to 10 bar
Pressure measurement and generation
Accuracy: ± 0,025% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg



€0.00 Price

Pressure range: -0.85 to 2 bar
Pressure measurement and generation
Accuracy: ± 0,025% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg



€0.00 Price

Pressure range: -0.85 to 7 bar
Pressure measurement and generation
Accuracy: ± 0,025% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg



€0.00 Price

Pressure range: -0.85 to 20 bar
Pressure measurement and generation
Accuracy: ± 0.05% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg

€0.00 Price

Pressure range: -0.85 to 10 bar
Pressure measurement and generation
Accuracy: ± 0.05% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg

€0.00 Price

Pressure range: -0.85 to 2 bar
Pressure measurement and generation
Accuracy: ± 0.05% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg

€0.00 Price

Pressure range: -0.85 to 7 bar
Pressure measurement and generation
Accuracy: ± 0.05% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg



€0.00 Price
  • Model : CTC-1200
  • Working range : 300 °C to 1200 °C
  • Resolution : 1 °C
  • Accuracy : ± 2 °C
  • Stability : ± 0.5 °C
  • Stabilization time : 15 minutes
  • Temperature display : °C / °F switchable
  • Well diameter : 26 mm
  • Immersion depth : 105 mm
  • Heating time (ambient to max.) : Approximately 60 minutes
  • Cooling time : Approximately 45 minutes (with forced air cooling)
  • Pressostat test : Suitable
  • Thermowell diameter : 8 mm
  • Power supply / consumption : 230V AC, 50 Hz / 115V AC, 60 Hz - 700 W - switchable
  • Instrument dimensions (L x W x H) : 160 x 365 x 450 mm
  • Instrument weight : 15 Kg

Measurement capacity :

  • Thermocouples : ISA Types J, K, R, S, N
  • RTD : Pt100 IEC Std.
  • mA : 0 to 25 mA
  • mV : 0 to 100 / 1000 mV
  • Volt : 0 to 10 V
  • Resistance : 0 to 500Ω / 3.5 KΩ

  • Temperature range: -100°C to +25°C
  • Accuracy: ± 0.3 °C
  • Stability: ± 0.05 °C
  • Resolution:Stabilization time: 15 minutes
    • 0.01°C (from +25 to +19.99°C)
    • 0.1°C (from 20°C to -100°C)
  • Temperature unit: Selectable °C or °F
  • Well diameter: 30 mm
  • Immersion length: 150 mm
  • Heating time: 50 minutes (from ambient to maximum)
  • Cooling time:Switch test: Provided
    • 40 minutes (from +25°C to -60°C)
    • 50 minutes (from -60°C to -100°C)
  • Power supply / Consumption: 90 ~ 220 V AC, 50/60 Hz
  • Dimensions (L x P x H) : 439 x 240 x 358 mm
  • Weight: 15 kg
  • Calibration certificate: Factory traceable to ISO17025 included or ISO17025 certificate from an accredited lab

CN-DT (Duo – Dual Cavities):

  • Cavity 1: +50 °C to 300 °C
  • Cavity 2: +250 °C to 600 °C
  • Accuracy: Less than 0.5% F.S. (Cavity 1 Min. 1 °C / Cavity 2 Min. 2 °C)
  • Stability: ± 0.5 °C
  • Resolution: 1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 30 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 450 x 410 x 190 mm / 14 kg
  • Calibration Certification: Factory with ISO17025 traceability included

CN-BT (Low Temperature):

  • Temperature Range: Ambient Temp. +10 °C to 350 °C
  • Accuracy: Less than 0.5% F.S. (Min. 1 °C)
  • Stability: ± 0.5 °C
  • Resolution: 0.1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included

CN-HT (High Temperature):

  • Temperature Range: 500 °C to 1200 °C
  • Accuracy: Less than 0.5% F.S. (Min. 3 °C)
  • Stability: ± 0.5 °C
  • Resolution: 1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 60 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included

CN-BT (Low Temperature):

  • Temperature Range: Ambient Temp. +10 °C to 350 °C
  • Accuracy: Less than 0.5% F.S. (Min. 1 °C)
  • Stability: ± 0.5 °C
  • Resolution: 0.1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included


Featured Products

For all clear, non biphasic liquids and all types of pipes from DN20 to DN 1200 : 

  • Measurement accuracy 1% F.S
  • Communications : 4~20 mA & RS485 Modbus
  • Programmable data logger 16 GB SD card
  • Battery 16 hours autonomy
  • Non-invasive transducers Stainless steel IP68
  • Mounting rails for optimal measurement
  • Energy metering included
  • 2x TT02 IP68 transducers
  • -40 °C ~ 80 °C (130°C optional)
  • Suitable for pipes DN 20 mm to DN 1200 mm
  • Mounting rails with strip and clamps
  • Standard cable length: 5 meters
  • 2x non-intrusive PT100 IP68 temperature sensors
  • Measurement of thermal & cooling energy

€2,500.00 Price
  • * Galvanic isolation
  • * No external power supply for configuration
  • * Write or read the configuration off-line by just connecting a PC
  • * Fault signal on sensor break or short circuit
  • * 2 wire technology, 4 to 20mA analogue output
  • * High accuracy in total ambient temperature range
  • * Customer specific measurement range setting or expanded SETUP

  • Communication : e-HART
  • Output : 4 to 20mA
  • Supply voltage : 7.5 to 45VDC
  • Input : RTC, TC, Ohm, mV
  • Cold junction : Internal 
  • Accuracy (Pt100) : <0,2K or 0,08%
  • Influence of ambient : Negligible 
  • Load influence : Negligible
  • Power supply influence : Negligible 
  • Resolution : 0.3uA
  • Installation : DIN Rail 

CN-BT (Low Temperature):

  • Temperature Range: Ambient Temp. +10 °C to 350 °C
  • Accuracy: Less than 0.5% F.S. (Min. 1 °C)
  • Stability: ± 0.5 °C
  • Resolution: 0.1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included

  • Storage temperature ; Atmospheric temperature
  • Operating ambient temperature : -20°C to +60° C
  • Media Temp : for rubber diaphragms 80 degree C max, higher with metal diaphragms
  • Can be offered for higher temperatures with other capsule combinaisons
  • Setpoint repeatability : ± 1% of FSR
  • Enclosure : Die cast aluminium to IP 66
  • Switch output : SPDT, DPDT, hermetically sealed, gold plated contacts
  • Process connection : 1/4 "BSP standard, other options like flanges, triclover clamps, diaphragm seals available
  • * Dimensions:   44mm×22.5mm(Φ×H)
  • * Output:   4 to 20mA
  • * Supply voltage:   11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
  • * Input:   RTD, TC, Ohm, mV
  • * Operation:   HART-protocol
  • * Galvanic isolation(In/Out):  2KVAC
  • * Installation:  sensor head Form B

CN-HT (High Temperature):

  • Temperature Range: 500 °C to 1200 °C
  • Accuracy: Less than 0.5% F.S. (Min. 3 °C)
  • Stability: ± 0.5 °C
  • Resolution: 1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 60 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included

Derniers produits
Pneumatic Pressure: -0.85 to 20 bar.
Hydraulic Pressure: 0 to 400 bar.
Accuracy: ±0.025% FS.
Temperature Compensation: Automatic from 0 to 50 °C.
Selectable Pressure Units: kg/cm², psi, bar, mbar, etc.
Current Input: 50 mA active, 25 mA passive, 800 Ω resistance.
Voltage Input: 0 to 30 VDC, resolution 0.01 (mA/V).
Switch Test: Up to 5 VDC.
Media: Air and oil.
Overpressure Alarm: 120% FS (visual and audible).
Pressure Generation: Built-in pumps with fine adjustment vernier.
Power Supply: Rechargeable 7.2 Volts (AA) battery.
Operating Temperature: 15 °C to 40 °C.
Storage Temperature Range: 10 °C to 60 °C.
Protection Class: IP10.
Zero Adjustment: Automatic if pressure is less than 1% FS.

  • Pneumatic Pressure: -0.85 to 20 bar.
  • Hydraulic Pressure: 0 to 400 bar.
  • Accuracy: ±0.025% FS.
  • Temperature Compensation: Automatic from 0 to 50 °C.
  • Selectable Pressure Units: kg/cm², psi, bar, mbar, etc.
  • Current Input: 50 mA active, 25 mA passive, 800 Ω resistance.
  • Voltage Input: 0 to 30 VDC, resolution 0.01 (mA/V).
  • Switch Test: Up to 5 VDC.
  • Media: Air and oil.
  • Overpressure Alarm: 120% FS (visual and audible).
  • Pressure Generation: Built-in pumps with fine adjustment vernier.
  • Power Supply: Rechargeable 7.2 Volts (AA) battery.
  • Operating Temperature: 15 °C to 40 °C.
  • Storage Temperature Range: 10 °C to 60 °C.
  • Protection Class: IP10.
  • Zero Adjustment: Automatic if pressure is less than 1% FS.
Models: PPC-H + (accuracy 0.025% FS)
Pressure Range: 0 to 400 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.
Models: PPC-H + (accuracy 0.025% FS)
Pressure Range: 0 to 200 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.
Models: PPC-H (accuracy 0.05% FS)
Pressure Range: 0 to 400 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.
Models: PPC-H (accuracy 0.05% FS)
Pressure Range: 0 to 200 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.

Pressure range: -0.85 to 10 bar
Pressure measurement and generation
Accuracy: ± 0,025% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg



€0.00 Price

Pressure range: -0.85 to 2 bar
Pressure measurement and generation
Accuracy: ± 0,025% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg



€0.00 Price
Best Seller Products
  • Accuracy: ± 1% of full scale
  • 12 Units: kPa, Pa, PSI, Kg / cm², Bar, mBar, MPa, Pa ...
  • Display: Large LCD screen with 4 DIGIT
  • Keys: On / Off, Reset, backlight
  • Connection: 1/4 ’’ G 
  • Dial size: 65 mm
  • All stainless steel fitting and housing
  • Max pressure recording & min.
  • Battery alarm function
  • Pressure diagram in%
  • Ease of use, robust design and reliable performance
  • Lithium battery 1 year autonomy in 24 hour operation

IN STOCK - Delivery within 48 hours max.

Order a calibration certificate >   

€90.00 Price
  • Accuracy: ± 1%
  • Speed: 0 ~ ± 12 m / s bidirectional
  • Display: Large LCD screen 4x16 characters
  • Menu in French
  • Communication: RS-232, 75-57600 bps
  • Built-in recorder: 2000 lines of recording data
  • Built-in Ni-MH battery, autonomy 12 hours in operation
  • Dimensions: 210 * 90 * 30 mm
  • Weight 0.5 kg
  • Choose your non-intrusive transducers between DN15 and DN6000
  • Mounting rails for transducers -30 to 90 ° C FREE

OFFER VALID UNTIL 31/03/2020

€1,490.00 Price
  • Accuracy: ± 0.4% of full scale
  • Units: kPa, Pa, PSI, Kg / cm², Bar, MPa
  • Display: Large LCD display with 5 DIGIT + Pressure bar graph
  • Keys: On / Off, Reset, backlight
  • Connection: 1/4 ’’ G 
  • Dial size: 80 mm
  • Max & min pressure recording
  • Battery alarm function
  • Ease of use, robust design and reliable performance
  • 2x Lithium battery

CALIBRATION CERTIFICATE >>

€145.00 Price
Newsletter
Inscription à la newsletter